Unique ID issued by UMIN | UMIN000030819 |
---|---|
Receipt number | R000029774 |
Scientific Title | Effective evaluation of the abdominal pressure device for stomach X-ray examination |
Date of disclosure of the study information | 2018/01/16 |
Last modified on | 2018/06/13 13:05:28 |
Effective evaluation of the abdominal pressure device for stomach X-ray examination
Effective evaluation of the abdominal pressure device for stomach X-ray examination
Effective evaluation of the abdominal pressure device for stomach X-ray examination
Effective evaluation of the abdominal pressure device for stomach X-ray examination
Japan |
malignant tumor
Gastroenterology | Gastrointestinal surgery | Radiology |
Others
NO
Effective evaluation of the abdominal pressure device for stomach X-ray examination
Efficacy
Confirmatory
Explanatory
Phase I
We compare the pillow to usually insert in the abdomen with the abdominal pressure device for stomach X-ray examination and inspect depiction range area in two folds of stomach anterior wall contrasting inspection. We perform it with a head low degree angle as uniformity for volunteers.
About an abdominal pressure device for stomach X-ray examination, We hear an abdominal pain by a questionnaire.
Interventional
Parallel
Randomized
Cluster
Single blind -participants are blinded
Dose comparison
2
Prevention
Maneuver |
We usually put pillows and, in two folds of stomach X-rays anterior wall contrasting photography, do it in head low degree, but We put an abdomen pressure device for developed stomach X-ray examination and compare the depiction range of both. In either case, it is said that the head low degree angle is constant. Time to need it is two minutes per 1 test person.
The intervention number of times to a subject is around two minutes only with one time of 1 test person
35 | years-old | <= |
60 | years-old | >= |
Male and Female
The test person who is the health condition that normal stomach X-ray examination is possible
We remove the following people. The test person whom others, a study person in charge, a study partaker judged to be inappropriate as a study subject more than dementia, stomach able person, 130 kg in weight.
50
1st name | |
Middle name | |
Last name | Shuichi Wakimoto |
Okayama University
Graduate School of Natural Science and Technology
3-1-1 Tsushima-naka kita-ku Okayama
086-251-8169
wakimoto@act.sys.okayama-u.ac.jp
1st name | |
Middle name | |
Last name | Koichi Shibuya |
Okayama University
Graduate School of Health Sciences
2-5-1 Shikata-cho kita-ku Okayama
086-235-6876
kshibuya@md.okayama-u.ac.jp
Graduate School of Natural Science and Technology
Graduate School of Natural Science and Technology
Other
NO
2018 | Year | 01 | Month | 16 | Day |
Unpublished
48 cases were investigated. But the effectiveness of the Remote Control Pressured Pillow was not found.
Completed
2017 | Year | 01 | Month | 20 | Day |
2017 | Year | 01 | Month | 20 | Day |
2018 | Year | 06 | Month | 13 | Day |
2018 | Year | 06 | Month | 13 | Day |
2018 | Year | 06 | Month | 13 | Day |
2018 | Year | 06 | Month | 13 | Day |
2018 | Year | 01 | Month | 15 | Day |
2018 | Year | 06 | Month | 13 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000029774
Research Plan | |
---|---|
Registered date | File name |
Research case data specifications | |
---|---|
Registered date | File name |
Research case data | |
---|---|
Registered date | File name |