Unique ID issued by UMIN | UMIN000031572 |
---|---|
Receipt number | R000036048 |
Scientific Title | Glidescope vs Macintosh laryngoscope at hemodynamic response in tracheal intubation: a systematic review and meta-analysis |
Date of disclosure of the study information | 2018/04/01 |
Last modified on | 2021/09/05 14:38:03 |
Glidescope vs Macintosh laryngoscope at hemodynamic response in tracheal intubation: a systematic review and meta-analysis
Glidescope vs Macintosh laryngoscope at hemodynamic response
Glidescope vs Macintosh laryngoscope at hemodynamic response in tracheal intubation: a systematic review and meta-analysis
Glidescope vs Macintosh laryngoscope at hemodynamic response
Japan |
Patients who need tracheal intubation with Glidescope or macintosh
Anesthesiology | Adult |
Others
NO
To investigate whether Glidescope attenuate the hemodynamic responses as compared with the Macintosh laryngoscope.
Safety,Efficacy
The outcome of this meta-analysis was to determine whether the Glidescope and the Macintosh laryngoscope reduce the hemodynamic responses -heart rate (HR) and mean blood pressure (MBP)-at 60, 120, 180, 300 second (s) after tracheal intubation.
Others,meta-analysis etc
18 | years-old | < |
100 | years-old | > |
Male and Female
We searched for all trials that compared measures associated with oral or nasal intubation between use of the Glidescope and use of the Macintosh laryngoscope for direct laryngoscopy in adult patients.
We excluded the studies that reported the parameters without the hemodynamic changes: i.e. HR and MBP.
800
1st name | Hiroshi |
Middle name | |
Last name | Hoshijima |
Saitama Medical University Hospital
Department of Anesthesiology
350-0495
Moroyama, Saitama, 350-0495, Japan
049-276-1271
hhoshi@saitama-med.ac.jp
1st name | Hiroshi |
Middle name | |
Last name | Hoshijima |
Saitama Medical University Hospital
Department of Anesthesiology
350-0495
Moroyama, Saitama, 350-0495, Japan
049-276-1271
hhoshi@saitama-med.ac.jp
Saitama Medical University Hospital, Department of Anesthesiology
Saitama Medical University Hospital, Department of Anesthesiology
Other
Teikyo University School of Medicine, Yokohama City University Graduate School of Medicine, International University of Health and Welfare
Saitama Medical University Hospital, Department of Anesthesiology
Moroyama, Saitama, 350-0495, Japan
049-276-1271
hhoshi@saitama-med.ac.jp
NO
2018 | Year | 04 | Month | 01 | Day |
https://upload.umin.ac.jp/cgi-bin/icdr/ctr_reg_list.cgi
Unpublished
https://upload.umin.ac.jp/cgi-bin/icdr/ctr_reg_list.cgi
634
The literature search identified 13 articles. HR and MBP at 60 s post-intubation was not significantly lower with the GlideScope than with the Macintosh .
2021 | Year | 09 | Month | 05 | Day |
We selected articles that included adults who had undergone tracheal intubation (oral or nasal) under general anesthesia. An article comparing HR and MBP measurements recorded before and after tracheal intubation with the GlideScope or Macintosh laryngoscope was included.
We independently assessed each of the two authors to determine if the extracted articles were suitable for our study selection. In addition, disagreements over the interpretation or analysis assignments of the data used in those extracted articles were resolved through discussion. If the results of a report may be duplicated and published, only the report that analyzes the latest data will be added to the meta-analysis. If we found missing or inconsistent data in the extracted articles, we contacted the author directly to retrieve the missing data and resolve the data inconsistencies.
none
the hemodynamic response, as indicated by HR and MBP at 60 s after tracheal intubation when indirect laryngoscope was performed,
Completed
2017 | Year | 02 | Month | 01 | Day |
2017 | Year | 01 | Month | 01 | Day |
2017 | Year | 02 | Month | 01 | Day |
2019 | Year | 01 | Month | 01 | Day |
none
2018 | Year | 03 | Month | 05 | Day |
2021 | Year | 09 | Month | 05 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000036048
Research Plan | |
---|---|
Registered date | File name |
Research case data specifications | |
---|---|
Registered date | File name |
Research case data | |
---|---|
Registered date | File name |