Unique ID issued by UMIN | UMIN000031591 |
---|---|
Receipt number | R000036070 |
Scientific Title | The volume effect of detectors for beam modeling of radiation treatment planning system and its impact on IMRT dose verification: The LDA-99SC versus the ion chamber. |
Date of disclosure of the study information | 2018/10/13 |
Last modified on | 2018/03/05 17:52:14 |
The volume effect of detectors for beam modeling of radiation treatment planning system and its impact on IMRT dose verification: The LDA-99SC versus the ion chamber.
The accuracy of IMRT dose verification by detectors used for beam modeling
The volume effect of detectors for beam modeling of radiation treatment planning system and its impact on IMRT dose verification: The LDA-99SC versus the ion chamber.
The accuracy of IMRT dose verification by detectors used for beam modeling
Japan |
Patients with head and neck cancer or prostate cancer who were treated with IMRT at Keiyukai Sapporo Hospital.
Surgery in general | Oto-rhino-laryngology | Urology |
Radiology |
Malignancy
NO
To investigate the volume effect of beam modeling detectors on IMRT dose verification.
Safety,Efficacy
Confirmatory
Pragmatic
Not applicable
The selection of a detector for appropriate beam modeling (LDA99 vs. ion chamber)
Others,meta-analysis etc
Not applicable |
Not applicable |
Male and Female
Twenty patients with head and neck cancer or prostate cancer receiving IMRT using Elekta Synergy Linac at Keiyukai Sapporo Hospital from January 2012.
Head and neck cancer patients treated with 4MV X-ray beam.
40
1st name | |
Middle name | |
Last name | Yuta kobayashi |
Keiyukai Sapporo Hospital
Department of Radiation Oncology
Kita1-1, Hondori 14, Shiroishi-ku, Sapporo, Hokkaido, Japan
+81-11-863-2101
kool008madd@gmail.com
1st name | |
Middle name | |
Last name | Nobuo Hongo |
Keiyukai Sapporo Hospital
Administrative office
Kita1-1, Hondori 14, Shiroishi-ku, Sapporo, Hokkaido, Japan
+81-11-863-2101
http://www.keiyukaisapporo.or.jp
nhongo@keiyukaisapporo.co.jp
Keiyukai Sapporo Hospital
Keiyukai Sapporo Hospital
Self funding
NO
2018 | Year | 10 | Month | 13 | Day |
Unpublished
Enrolling by invitation
2012 | Year | 01 | Month | 04 | Day |
2012 | Year | 01 | Month | 11 | Day |
In radiation therapy strategies, the treatment planning system (TPS) is dispensable for simulate the absorbed dose distribution in patients is indispensable. The dose distribution is calculated using the beam model created from the beam profile that is unique to each Linac, but the model greatly differs depending on detector used for profile measurements. Particularly in intensity-modulated radiation therapy (IMRT) and stereotactic radiotherapy (SRT) that use many small irradiation fields, the difference in beam model has large influence on the dose calculation results, and it is necessary to select an appropriate detector to evaluate dose distribution accurately.
2018 | Year | 03 | Month | 05 | Day |
2018 | Year | 03 | Month | 05 | Day |
Value
https://center6.umin.ac.jp/cgi-open-bin/ctr_e/ctr_view.cgi?recptno=R000036070
Research Plan | |
---|---|
Registered date | File name |
Research case data specifications | |
---|---|
Registered date | File name |
Research case data | |
---|---|
Registered date | File name |